德國Sensor- und Lasertechnik Dr. W. Bohmeyer傳感器
德國Gefa Processtechnik GmbH閥門
產(chǎn)品列表:
軟層次蝶閥
聚四氟乙烯襯里蝶閥
雙偏心閥
節(jié)流閥
法蘭球閥
3件式球閥
兩件式球閥
1件式球閥
刀閘閥
非止回閥
執(zhí)行器
:王工
同號
449147851
價注意事項:
1.請發(fā)書面詢價函(郵件,,傳真等),不接受口頭報價。
2.如果型號不能*對上,請?zhí)峁┯⑽钠放泼?具體型號+數(shù)量。
3.詢價的商友請主動告知公司名稱和,謝謝。
Soft-seated butterfly valve KG9 2-piece, wafer type with GEFA-MULTITOP Automation system | Soft-seated butterfly valve KG7 2-piece, lug type with GEFA-MULTITOP Automation system | Soft-seated butterfly valve KG2 1-piece, wafer type with GEFA-MULTITOP Automation system | ||||
Soft-seated butterfly valve K19 2-piece, wafer type | Soft-seated butterfly valve K17 2-piece, lug type | Soft-seated butterfly valve KG4 1-piece, lug type with GEFA-MULTITOP Automation system | ||||
Soft-seated butterfly valve K08 1-piece, wafer type | Soft-seated butterfly valve K07 1-piece, lug type | Soft-seated butterfly valve K11 2-piece, wafer type | ||||
The types | |
KG 9 | |
KG 7 | |
K 19 | |
K 17 | |
K 11 | |
KG 2 | |
KG 4 | |
K 08 | |
K 07 |
Series PEM
Pyroelectric detector with black very broadband absorption coating
Type | energy range | diameter |
PEM 4 | 1µJ - 20 mJ | 4 mm |
PEM 8 | 2µJ - 75 mJ | 8 mm |
PEM 11 | 3 µJ - 150 mJ | 11 mm |
PEM 21 | 5 µJ - 500 mJ | 21 mm |
PEM 34 | 15 µJ - 1,4 J | 34 mm |
Series PEM HP
Pyroelectric Detector with black coating for high average power
Type | energy range | diameter |
PEM 20 HP | 15µJ - 500 mJ | 20 mm |
PEM 45 HP | 30µJ - 2 J | 45 mm |
Series PEM K
Pyroelectric detector with ceramic absorption coating for high energy density, best for Excimer and YAG-laser
Type | energy range | diameter |
PEM 45 K | 1 mJ - 15 J | 45 mm |
PEM 20 K | 500 µJ - 3 J | 20 mm |
PEM 45 K USB | 1 mJ - 1 J | 45 mm |
Series PEM USBnew
Pyroelectric Detector with USB output
Type | energy range | diameter |
PEM 45USB | 100 µJ - 200mJ | 45 mm |
PEM 45 K USB | 1mJ - 1J | 45 mm |
Series PEM E
mit integrated preamplifier
Type | energy range | diameter |
PEM 12 E | 500 nJ - 15 mJ | 12 mm |
Series PEM HiRep
Pyroelectric detector for high repetition rates
Type | energy range | diameter |
PEM 12 HiRep | 30 µJ - 100 mJ | 12 mm |
PEM 12 HiRep UV | 30 µJ - 60 mJ | 12 mm |
PEM 24 HiRep | 30 µJ - 350 mJ | 12 mm |
PEM 24 HiRep UV | 30 µJ - 250 mJ | 12 mm |
Series VUV
Pyroelectric detector specially designed for VUV - 157nm
Type | energy range | diameter |
PEM 10 VUV | 100µJ - 40 mJ | 10 mm |
PEM 20 VUV | 150µJ - 150 mJ | 20 mm |
PEM 24 VUV | 5 µJ - 400 mJ | 24 mm |
PEM 30 K VUV | 1 mJ - 5 J | 30 mm |
Pyroelectric OEM - Sensors
For installation as energy monitors in lasers or for customer specified solution
Series PES
Type | sensitivity [V/J] | repetition rate [Hz] | dimensions |
PES 4 | 500..1000 at 1 MOhm | 80 Hz at 1 MOhm | 7 x 9,5 mm², M 3 |
PES 8 | 200..500 at 1 MOhm | 40 Hz at 1 MOhm | 11 x 9,5 mm², M 3 |
PES 11 | 100..400 at 1 MOhm | 40 Hz at 1 MOhm | 14 x 9,5 mm², M 3 |
PES 21 | 50..150 at 1 MOhm | 25 Hz at 1 MOhm | 24 x 9,5 mm², M 4 |
PES 34 | 40.. 70 at 1 MOhm | 25 Hz at 1 MOhm | 37 x 10 mm², M 4 |
PES 4HR | 1000..1500 at 1 MOhm | 250 Hz at 1 MOhm | 7 x 9,5 mm², M 3 |
PES 8 HR | 700..900 at 1 MOhm | 150 Hz at 1 MOhm | 11 x 9,5 mm², M 3 |
PES 11 HR | 400..600 at 1 MOhm | 250 Hz at 1 MOhm | 14 x 9,5 mm², M 3 |
PES 21 HR | 150..250 at 1 MOhm | 50 Hz at 1 MOhm | 24 x 9,5 mm², M 4 |
Series PEO
PEO 8 | PEO 8A | PEO 12 | PEO 12A | |
diameter | Ø 8 mm | Ø 8 mm | Ø 12 mm | Ø 12mm |
rep rate | 1kHz at 1 MOhm | 10 kHz | 700 Hz at 1MOhm | 3 kHz |
sensitivity | 400..500 V/J at 1MOhm | 1000..25000 V/J | 300..400 V/J at 1 MOhm | 1000..15000 V/J |
Thermophile detectors
Series HP and BB
BB 25 | HP 25 | HP 50 | HP 25 S | HP 25/ 50 | ||
active diameter | 25 mm | 25 mm | 50 mm | 25 mm | 25 mm | |
max. power | 10 W | 10 W | 30 W | 10 W | 50 W | |
max. power density | 20 W/cm² | 20 W/cm² | 20 W/cm² | 20 W/cm² | 40 W/cm² | |
dimensions [mm] | Ø 120 x 80 | Ø 120 x 80 | Ø 150 x 80 | Ø 90 x 32 | Ø 120 x 80 | |
sensitivity | 70 mV/W .. 150 mV/W | |||||
conncetor | BNC |
Series LP
Type | power range | diameter |
LP 20 | 50 µW - 3 W | 20 mm |
Readout Units
Type | Description |
LEM 2410 | Pulse Energy and Power Mesurement Instrument |
PM 200 | Laser Energy Meter with high dynamic range |
LM 100 | Laser Power Meter |
Accessories
Type | Description |
Preamplifier | Preamplifier for Pyroelectric Energy Sensors |
Isolation kit | Attachment for PEM 30K VUV |
Resistance Thermometers
Resistance thermometers based on Pt-100 / Pt-1000 sensors - product survey
The product range of resistance thermometers of EPHY-MESS is classified into 4 segments. The temperature detectors are differentiated by its design - the housing or the customizing of the Pt-100 sensors.
(Pt-100 / Pt-1000 characteristic curves and technical data)
Catalogue download |
|
Cable resistance thermometer
Standard types
Cable resistance thermometer type (M-xx/xSH)
Temperature sensor type xx (xx=look at precision resistors) single (ESH) or double (DSH) insulated with shrinking tube and fix connected supply line by 2, 3 or 4 conductor circuitry.
Cable resistance thermometer type (M-xx/MH)
Temperature sensor built in a stainless steel sleeve, with fix connected supply line by 2, 3 or 4 conductor circuitry.
Cable resistance thermometer type(M-xx/KH)
Temperature sensor sealed in ceramic sleeve with fix connected supply line by 2, 3 or 4 conductor circuitry
Type: M-xx/xSH | Type: M-xx/MH | Type: M-xx/KH |
Special designs
- humidity protected sensor (IP65)
- high voltage resitance up to 5kV (higher voltages on request)
- with copper or nickel precision resistors
- measuring range up to +400°C
- ATEX certified versions
Areas of application
- measurements in laboratories and experimental plants
- measurements of the room air and other gases
- measurement of the temperature at difficult accessible and distant places
- measurement in the ground and water
- inside the windings, slots and housings of electrical machines (M-xx/xSH, M-xx/KH)
- inside pumps and compressors
- traffic, wind power and environment technique
- Medicine technique
2. Screw-in thermometers
Special designs
Screw in thermometer type (M-xx/SGH),
Temperature sensor type xx (xx=look at precision resistors) sealed in a screw housing with supply line or plug.
Screw in thermometer type: M-xx/SGH with single wires, | with hose line and strain relief, | with plug |
Screw in thermometer type (xESWT-EM24/38),
One (x=E) or two (x=D) temperature sensors built in a stainless steele protection tube, diameter 6mm (standard). Compact connection head type EM24/EM38 with clamp socket and / or fix connected cable. The number (24/38) indicates the diameter of the used connection head. For the assembly we deliver shiftable or fix screwings matching to the protection tube diameter. On request both versions are available with ATEX approval and sealed connection heads
Screw in thermometer type: EM24 |
Screw in thermometer type (xESWT-y),
One (x=E) or two (x=D) temperature sensors built in a stainless steel protection tube with connection head form A (y=A) or B (y=B). Electively with fix or movable screwing.
Screw in thermometer type: EESWT-B without screwing |
Screw in thermometer type:(xESWT-MA),
One (x=E) or two (x=D)Temperature sensors built in a stainless steel protection tube with connection head form MA / J. Fix or moveable screwing on request.
Screw in thermometer type: xESWT-MA without screwing |
Features
- measuring range up to +400°C
- small connector heads for the types EM24 and MA
- On request, protection tube insulation with PTFE or elastomere
- simple and quick assembly
- fastening with screw neck or flange
- protection tube diameter: 6, 8, 9 and 11 mm, protection tube length: 40...1500mm.
- Ex-protected design according to ATEX, available for EM24/38 series
Areas of application
- measurement of bearing temperatures
- mechanical engineering
- applications in laboratories
- measurement of temperatures in containers and tubes
- in Ex hazardous areas
- chemical industry
3. Plug in resistance thermometer
Bayonet plug-in thermometer (xESWT-BV),
One (x=E) or two (x=D) temperature sensors built in a stainless steel sleeve with fix connected supply line. Electively with straight or square cable exit. The connection is arranged by 2, 3 or 4 conductor circuitry. At the plug-in of the detector into the assigned borehole and locking of the bayonet-joint, a defined contact pressure is created, which guarantees a very good thermal interconnection.
Plug-in thermometer with bayonet catch type: EESWT-BV in straight and angular design |
Advantages
- measuring range up to +260°C
- short response times by means of mechanical initial tension
- available with fix or adjustable bayonet-joint
- straight or angular design
- simple and quick assembly
Areas of application
- electrical motors
- generators and transformers
- bearings and driving elements
- tubes and containers
4. Jacket resistance thermometers
Jacket resistance thermometer type (WT-MI),
Into a metallic protection sleeve a measurement resistor is inserted and tightly pressed into ceramic powder. This sleeve is lengthened with a bendable, mineral insulated line (MI-line) up to the desired final measure and the line ends are ready-made according to the customer's request. The supply lines are insulated against the jacket.
WT-MI: with Lemosa plug (top), with connection sleeve and hose line (below) |
Advantages
- small diameters are possible (<2mm)
- measuring range up to +600°C
- extremely sturdy and vibration resistant
- bendable in small radius
- with free wire ends or Lemosa plug connections
Areas of application
- in containers, tubes, apparatus and machines
- in driving and brake elements
- in gaseous and liquid mediums