FEATURES
??SIL2 Certified IEC 61508*
??High Accuracy: .01% of Full Scale
??Superior Piezo Ceramic Sensor (Patent # 5,473,245)
??Local Indication with LCD Display
??Single & Double Tri-Clamp Installations
??Suitable for CIP & SIP Applications
??180 Grit Polish Standard
??Never Requires Re-Calibration: Set It & Forget It
??Dual Compartment Housing with Separate Field Terminal Compartment
??Pressure to 1750 psig (120.7 bar)
??Temperature Range: -320 to 450º F (-196 to 232ºC) with options
??Field Replaceable / Upgradable Electronics Module
??Built In RFI / EMI Filter
??Digital Communication
OPTIONS
??240 Grit & Electropolished Finish
??20 Point Strapping Table
??Temperature Indication
??Foundation Fieldbus
??Honeywell DE Output
??Glass Viewing Window
??316L Stainless Steel Enclosure
??Flexible Waveguide for Low Headroom Applications
SPECIFICATIONS
Electronic Transmitter
Housing type Explosion Proof Powdered Coated Cast Aluminum or Stainless Steel, Dual Compartment
Electrical Connection 1/2” FNPT or M20
Repeatability 0.005% of full scale or 0.015”, whichever is greater
Non-Linearity 0.01% of full scale or 0.035”, whichever is greater
Accuracy 0.01% of full scale or 0.050”, whichever is greater
Supply Voltage 13.5 to 36 VDC - Loop Powered; 9 to 32 VDC - Foundation Fieldbus
Reverse Polarity Protection Diode in series with loop
Output Standard 4-20 mA DC Loop
HART protocol (Standard)
Foundation Fieldbus (optional)
??ITK 5.1.0 Compliant
??5 AI and 1 PID blocks
??12.5 mA Quiescent Current Draw
??LAS Capable
Honeywell DE (optional)
Damping Field adjustable by means of pushbuttons. Range: 0.1 to 36 seconds
Burnout Jumper selectable upscale (21 mA) or downscale (3.6 mA)
Temperature -40 to 170ºF (-40 to 77ºC) Ambient
Humidity 0 to 99% R.H., non-condensing
* Transmitters equipped with single level 4-20mA/HART module option only
* Refer to “Ordering Information” Section G
SPECIFICATIONS
Sensor Tube
Material 316L Stainless Steel
Process Temp. -320 to 450ºF (-196 to 232ºCºC) with options
Max. Press. 1750 psig @ 450ºF (120.7 bar @ 232ºC) actual rating will be determined by process connection
Probe Length 1 to 30 feet (304.8mm to 9.14m)
Mounting Tri-Clamp fitting standard; Refer to ordering information for options.